TC-327-60-6.2 meters permanent magnet industrial large ceiling fan

Taicheng permanent magnet industrial large fan can produce the best three-dimensional natural wind effect that the human body can feel, with a large coverage area and soft wind speed. In actual use, the ventilation and temperature brought by the human body can be reduced by 5-8 degrees Celsius. The maximum operating power of each fan Only 1.5kW, the product is beautiful, durable, and maintenance-free, creating comfort for you.
Send Inquiry

Product Details

product description


The diameter coverage of Taicheng permanent magnet industrial ceiling fans is 4.2 meters to 8 meters. The characteristics of our products are that they can push a large amount of air most effectively, generate super large air volume, form a full range of ground coverage and air three-dimensional circulation, and completely solve the problem of tall spaces. The problem of ventilation and cooling is difficult. According to our experimental data, Taicheng permanent magnet industrial large fans can produce the best three-dimensional natural wind effect that the human body feels, with a large coverage area and soft wind speed. Ventilation and cooling 5-8 degrees Celsius. The maximum operating power of each fan is only 1.5kW. The product is beautiful, durable, and maintenance-free, creating comfort for you.

4


Features


1. ABB electromagnetic scheme, no carbon brush, no Hall, direct drive, high torque, permanent magnet brushless DC motor.

2. Power saving, first-class energy efficiency.

3. Low noise (the highest standard in the country), it can be installed in cinemas.

4. Reasonable structure, the easiest and safest installation.

5. The product performance is 100 percent stable, no vibration, no noise.

6. The U.S. Bass Wind Tunnel Laboratory guides the design of the fan blade, which is made of aviation materials, and it will not break when it is bent at 90 degrees.

7. 3 bearings installed, imported brand.

3.jpg



Product parameters

model

diameter
(m)

power
(KW)

Voltage
(V)

frequency
(HZ)

number of blades
(pcs)

Rotating speed
(rpm)

air volume
(m³\/min)

noise
(DB)

Effective area
(㎡)

coverage area
(㎡)

weight
(kg)

TC-327-60

8

1.5

380

50\/60

6

50

15000

45

800

1600

175

TC-327-60

7.3

1.5

380

50\/60

6

55

13500

45

700

1500

165

TC-327-60

6.2

1.5

380

50\/60

6

65

12000

45

630

1100

150

TC-327-60

5.2

1.1

380

50\/60

6

85

11000

45

500

850

142

TC-132-40

4

0.75

220

50\/60

6

95

9200

45

380

800

130

TC-132-40

3.5

0.75

220

50\/60

6

95

3750

40

120

750

48

TC-112-20

3

0.55

220

50\/60

6

105

2800

40

95

700

44

TC-112-20

2.5

0.55

220

50\/60

6

115

2200

40

80

650

40



working principle


Taicheng Fan integrates foreign advanced aviation technology and the most stringent safety structure abroad to develop a large propeller fan with outstanding performance. The propeller blades manufactured by aerodynamic principles and advanced technology can generate super large area of ​​natural wind, In this way, the space is formed to send cold air in the horizontal direction and squeeze the air in the vertical direction to extrude the hot air to the outside, and finally achieve a large-area three-dimensional flow air system to achieve a more comfortable effect.

When the big fan rotates, the blades drive the airflow, and the airflow moves downward along the angle of the blades. When the downwardly moving airflow hits the ground, it refracts and moves outward. This airflow refracted outward is called horizontal jet, which is relatively Depending on the diameter of the fan, a large-area cylindrical three-dimensional wind is formed under the continuous flow of airflow. When the continuous jet pressure flow reaches its potential, it will move outward until it encounters a side wall or other vertical Surface, so the cylindrical three-dimensional wind is often several times larger than the diameter of the fan. This three-dimensional moving airflow will destroy the moisture-saturated boundary layer around the body and accelerate evaporation, thereby producing a cooling effect.

Under ideal conditions, the horizontal height of the outward spray is equal to the radius of the fan blade, that is, the ground spray height generated by a fan with a diameter of 7.3 meters is 3.65 meters, but the actual spray height will be smaller than the ideal state due to on-site reasons, but the reduction The height of the small back is enough to engulf a person or a cow standing on the ground, which is the original purpose of this product.


风扇气流



6 major features


360-degree all-round air circulation ventilation without blind spots


Large air volume and wide coverage

The air circulation per minute is 13800m³, and the maximum coverage area of ​​a single machine can reach 1000 square meters.

Energy efficient

The effect of IE5 energy-saving motor is further improved, more energy-saving, and the actual power consumption is 0.8-1.2 kilowatts per hour.

Stable quality

Simple process, advanced structure, high-end configuration, high quality stability and outstanding performance.

Long life, professional worry-free service

Innovative technology, low speed, no wear, no maintenance, design life of 15 years; Taicheng has 15 years of industry-leading service experience, has a large number of application cases, and provides users with unique high-value station solutions.

Good and effective, super cost-effective

The plant area is too large, the cost of installing air conditioners is too high, the general ventilation equipment is useless, and the large fan achieves a good comprehensive effect with a small investment.

replace air conditioner

It can make the human body feel the temperature difference effect of about 5-7 degrees, and some places can be used in combination with traditional air conditioners, so as to achieve the effect of replacing central air conditioners to a certain extent.



5 big insurance


Spirit level (optional)

Uncertain factors such as collisions and typhoons during use will cause the overall shaking angle of the motor to be greater than or equal to 8 degrees, and immediately trigger an automatic insurance alarm and immediately cut off the power supply to prevent accidents.


Upper and lower insurance

The upper and lower insurance pieces connect the fan blades and the chassis as a whole, interconnected and mutually insured. The coupling interference and anti-falling device, even if the chassis screws break accidentally, the entire chassis

The disk cannot fall down when it falls on the anti-falling plate, ensuring nothing goes wrong.


Chassis insurance

Taking the lead in using 40Cr steel material, the high-strength integral blisk made by laser cutting technology effectively avoids potential cracks in low-pressure casting.

Force, fatigue and other issues; supplemented by precise and strict dynamic balance test, to ensure the high balance stability of the equipment and improve the safety performance of the equipment.


Tension sleeve

The main shaft increases the design of the tension sleeve to increase the connection and stability of the aluminum wheel and the motor.


wire rope

The tensile strength of each wire lock can reach 1000kg, which can ensure the safety and make the fan run smoothly and increase the service life.



Structural Analysis Diagram

吊扇结构图.jpg


installation conditions

安装条件.jpg


Airflow diagram

气流示意图.jpg


Application field




How to use the ceiling fan controller


Power on: Turn on the switch of the power cord, wait for the display panel of the controller to light up, close the door, turn on the speed control knob on the controller (from left to right), at this time the fan motor starts to rotate, and the fan speed increases at this time, Stop when it is adjusted to the required speed, and then use it normally.

Shutdown: adjust the knob switch of the controller (rotate counterclockwise), at this time the fan speed will slow down, and stop when it is adjusted to the slowest speed, turn off the switch on the controller (turn from right to left), and the fan motor will stop rotating at this time, Turn off the power switch. (Note: be careful to turn off the power directly, because the fan needs deceleration time to turn off the power. Directly switching off the power will cause the fan that is rotating at high speed to slow down in a short time. The failure caused by this illegal operation is not covered by the manufacturer. covered by the warranty).

Note: Before turning on the fan, it must be observed to ensure that there are no obstacles around the fan that may touch the fan blades, so as not to cause harm to personnel or equipment.



maintenance


Every autumn when the weather cools down, the fan needs to be overhauled and maintained after the fan is stopped.

1. Check the tightness of the 4 cable-stayed wire ropes. If the wire ropes are found to be loose, adjust the turnbuckle screws to keep the wire ropes in a tight state.

2. Check the fixing screws of the ceiling bracket and the hanging rod. If the screws are found to be loose, adjust the fixing screws.

3. Check the connecting screws of the blades. If the screws are found to be loose, adjust the fastening screws.

4, Clean the dirt on the surface of the blade and the host.



Troubleshooting


1. For operation and control faults, follow the alarm numbers displayed on the controller, and check the fault codes corresponding to the controller manual to eliminate them. If it cannot be eliminated on site, contact the supplier.

2. The drive motor is faulty, such as excessive motor noise, abnormal noise, and motor vibration, please contact the supplier.



This product belongs to large-scale industrial ventilation and cooling equipment. Customers can consult customer service according to their own needs. The company can arrange professional docking. The price of the product is a deposit. Please do not take pictures privately. For the cost, please consult customer service at Wangwang or call 18957625590